TY - JOUR
T1 - Shake table tests on nonlinear steel fuses for the acceleration-control of nonstructural components
AU - Elkady, Ahmed
AU - Kazantzi, Athanasia K.
AU - Dietz, Matt
AU - Dihoru, Luiza
AU - De Risi, Raffaele
AU - Vamvatsikos, Dimitrios
AU - Lignos, Dimitrios G.
AU - Miranda, Eduardo
AU - Mylonakis, George
N1 - Publisher Copyright:
© The Author(s) 2025. This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
PY - 2025
Y1 - 2025
N2 - During recent major earthquakes, modern seismically designed buildings have demonstrated a low risk of collapse and life-safety limit states. However, both direct and indirect economic losses are often primarily due to damage to nonstructural components. This damage can be significant even under the more frequent low- or moderate-intensity earthquakes, as corroborated by system-level numerical studies, since it can result in greatly amplified forces and accelerations transmitted into the nonstructural components. Recent numerical research has demonstrated that this can be affordably and practically done by connecting the component to the structure via sacrificial controlled-strength steel fuses, designed to yield at desirable force levels and hence limiting the forces and damage in the nonstructural component. A shake table testing campaign was undertaken at the University of Bristol to experimentally validate this concept. The tests involved 14 specimens comprising different masses and tuned fuse geometries subjected to recorded floor motions, resulting in a total of 45 dynamic tests. The testing campaign, the instrumentation, the processing, and deduction of the response histories are described in detail. The resulting dataset is curated, organized, and made publicly available through an online repository to support further numerical and computational research on damage-free structures.
AB - During recent major earthquakes, modern seismically designed buildings have demonstrated a low risk of collapse and life-safety limit states. However, both direct and indirect economic losses are often primarily due to damage to nonstructural components. This damage can be significant even under the more frequent low- or moderate-intensity earthquakes, as corroborated by system-level numerical studies, since it can result in greatly amplified forces and accelerations transmitted into the nonstructural components. Recent numerical research has demonstrated that this can be affordably and practically done by connecting the component to the structure via sacrificial controlled-strength steel fuses, designed to yield at desirable force levels and hence limiting the forces and damage in the nonstructural component. A shake table testing campaign was undertaken at the University of Bristol to experimentally validate this concept. The tests involved 14 specimens comprising different masses and tuned fuse geometries subjected to recorded floor motions, resulting in a total of 45 dynamic tests. The testing campaign, the instrumentation, the processing, and deduction of the response histories are described in detail. The resulting dataset is curated, organized, and made publicly available through an online repository to support further numerical and computational research on damage-free structures.
KW - acceleration-sensitive
KW - component nonlinearity
KW - dynamic amplification
KW - floor spectra
KW - Nonstructural components
KW - shake table test
KW - structural fuse
UR - https://www.scopus.com/pages/publications/105010359003
U2 - 10.1177/87552930251348159
DO - 10.1177/87552930251348159
M3 - Article
AN - SCOPUS:105010359003
SN - 8755-2930
JO - Earthquake Spectra
JF - Earthquake Spectra
M1 - 87552930251348159
ER -