Abstract
This letter proposes a safe operating area (SOA) concept for film capacitors in dc-link applications. The SOA is presented by capacitor voltage and ripple current, considering the impact of ambient temperature, degradation, and parameter variance. The theoretical derivations and proof-of-concept experimental verifications are given.
Original language | British English |
---|---|
Article number | 9399804 |
Pages (from-to) | 11014-11018 |
Number of pages | 5 |
Journal | IEEE Transactions on Power Electronics |
Volume | 36 |
Issue number | 10 |
DOIs | |
State | Published - Oct 2021 |
Keywords
- DC-link
- film capacitor
- safe operating area (SOA)