TY - GEN
T1 - Retinal image quality analysis for automatic diabetic retinopathy detection
AU - Pires, Ramon
AU - Jelinek, Herbert F.
AU - Wainer, Jacques
AU - Rocha, Anderson
PY - 2012
Y1 - 2012
N2 - Sufficient image quality is a necessary prerequisite for reliable automatic detection systems in several healthcare environments. Specifically for Diabetic Retinopathy (DR) detection, poor quality fund us makes more difficult the analysis of discontinuities that characterize lesions, as well as to generate evidence that can incorrectly diagnose the presence of anomalies. Several methods have been applied for classification of image quality and recently, have shown satisfactory results. However, most of the authors have focused only on the visibility of blood vessels through detection of blurring. Furthermore, these studies frequently only used fund us images from specific cameras which are not validated on datasets obtained from different retinographers. In this paper, we propose an approach to verify essential requirements of retinal image quality for DR screening: field definition and blur detection. The methods were developed and validated on two large, representative datasets collected by different cameras. The first dataset comprises 5,776 images and the second, 920 images. For field definition, the method yields a performance close to optimal with an area under the Receiver Operating Characteristic curve (ROC) of 96.0%. For blur detection, the method achieves an area under the ROC curve of 95.5%.
AB - Sufficient image quality is a necessary prerequisite for reliable automatic detection systems in several healthcare environments. Specifically for Diabetic Retinopathy (DR) detection, poor quality fund us makes more difficult the analysis of discontinuities that characterize lesions, as well as to generate evidence that can incorrectly diagnose the presence of anomalies. Several methods have been applied for classification of image quality and recently, have shown satisfactory results. However, most of the authors have focused only on the visibility of blood vessels through detection of blurring. Furthermore, these studies frequently only used fund us images from specific cameras which are not validated on datasets obtained from different retinographers. In this paper, we propose an approach to verify essential requirements of retinal image quality for DR screening: field definition and blur detection. The methods were developed and validated on two large, representative datasets collected by different cameras. The first dataset comprises 5,776 images and the second, 920 images. For field definition, the method yields a performance close to optimal with an area under the Receiver Operating Characteristic curve (ROC) of 96.0%. For blur detection, the method achieves an area under the ROC curve of 95.5%.
KW - Blur Detection
KW - Field Definition
KW - Retinal Quality Assessment
UR - http://www.scopus.com/inward/record.url?scp=84872416503&partnerID=8YFLogxK
U2 - 10.1109/SIBGRAPI.2012.39
DO - 10.1109/SIBGRAPI.2012.39
M3 - Conference contribution
AN - SCOPUS:84872416503
SN - 9780769548296
T3 - Brazilian Symposium of Computer Graphic and Image Processing
SP - 229
EP - 236
BT - Proceedings - 25th SIBGRAPI
T2 - 25th Conference on Graphics, Patterns and Images, SIBGRAPI 2012
Y2 - 22 August 2012 through 25 August 2012
ER -