N2 - Ammonia (NH3) toxicity, stemming from nitrification, can adversely affect aquatic life and influence the taste and odor of drinking water. This underscores the necessity for highly responsive and accurate sensors to continuously monitor NH3 levels in water, especially in complex environments, where reliable sensors have been lacking until this point. Herein, we detail the development of a sensor comprising a compact and selective analyzer with low gas consumption and a timely response based on photoacoustic spectroscopy. This, combined with an automated liquid sampling system, enables the precise detection of ammonia traces in water. The sensor system incorporates a state-of-the art quantum cascade laser as the excitation source emitting at 9 μm in resonance with the absorption line of NH3 located at 1103.46 cm-1. Our instrument demonstrated detection sensitivity at a low ppm level for the ammonia molecule with response times of less than 60 s. For the sampling system, an ammonia stripping solution was designed, resulting in a prompt full measurement cycle (6.35 min). A further evaluation of the sensor within a pilot study showed good reliability and agreement with the reference method for real water samples, confirming the potential of our NH3 analyzer for water quality monitoring applications.
AB - Ammonia (NH3) toxicity, stemming from nitrification, can adversely affect aquatic life and influence the taste and odor of drinking water. This underscores the necessity for highly responsive and accurate sensors to continuously monitor NH3 levels in water, especially in complex environments, where reliable sensors have been lacking until this point. Herein, we detail the development of a sensor comprising a compact and selective analyzer with low gas consumption and a timely response based on photoacoustic spectroscopy. This, combined with an automated liquid sampling system, enables the precise detection of ammonia traces in water. The sensor system incorporates a state-of-the art quantum cascade laser as the excitation source emitting at 9 μm in resonance with the absorption line of NH3 located at 1103.46 cm-1. Our instrument demonstrated detection sensitivity at a low ppm level for the ammonia molecule with response times of less than 60 s. For the sampling system, an ammonia stripping solution was designed, resulting in a prompt full measurement cycle (6.35 min). A further evaluation of the sensor within a pilot study showed good reliability and agreement with the reference method for real water samples, confirming the potential of our NH3 analyzer for water quality monitoring applications.
UR - https://www.scopus.com/pages/publications/85191811400
U2 - 10.1021/acsomega.3c10175
DO - 10.1021/acsomega.3c10175
M3 - Article
AN - SCOPUS:85191811400
SN - 2470-1343
VL - 9
SP - 19127
EP - 19135
JO - ACS Omega
JF - ACS Omega
IS - 17
ER -