Abstract
This letter proposes a novel compensation method to eliminate the impact of parasitic inductances on the measurement accuracy of on-state voltage of power semiconductor devices in operating converters. It is an online and noninvasive method by measuring the output current of inverter and on-state voltage of power device only. The impact of parasitic inductances and its compensation are verified experimentally through a traction inverter system.
Original language | British English |
---|---|
Pages (from-to) | 4937-4941 |
Number of pages | 5 |
Journal | IEEE Transactions on Power Electronics |
Volume | 37 |
Issue number | 5 |
DOIs | |
State | Published - 1 May 2022 |
Keywords
- Compensation
- on-state voltage
- parasitic inductance
- power semiconductor