TY - JOUR
T1 - Multiperiod optimization of cooling water system with flexible topology network
AU - Liu, Bo
AU - Zhang, Ruimei
AU - Liu, Ye
AU - Wang, Yufei
AU - Almansoori, Ali
AU - Feng, Xiao
N1 - Publisher Copyright:
© 2023 Institute of Process Engineering, Chinese Academy of Sciences.
PY - 2023
Y1 - 2023
N2 - Cooling water systems (CWSs) are extensively utilized in various industries to eliminate the excess heat and converse energy. Studies on CWSs mainly concentrated on finding the optimal cooler network structure. In addition, some works also considered the optimal design under varied operation conditions. However, in these works, once the optimal design of the cooler's network is determined, its arrangement remains fixed and cannot be adapted to accommodate diverse operating conditions. In this work, a flexible topology network concept is proposed to make the adjustment of network structure possible under different operation conditions. The CWS with integrated air cooler and flexible topology network has better overall performance, represented by a mixed integer nonlinear programming (MINLP) model that require advanced tools such as GAMS software. Case studies revealed that the proposed methodology can realize better energy-saving performance, and improve the economic performance under varied operation conditions. The impact of critical flexible nodes on system configuration and economy is achieved by sensitivity analysis.
AB - Cooling water systems (CWSs) are extensively utilized in various industries to eliminate the excess heat and converse energy. Studies on CWSs mainly concentrated on finding the optimal cooler network structure. In addition, some works also considered the optimal design under varied operation conditions. However, in these works, once the optimal design of the cooler's network is determined, its arrangement remains fixed and cannot be adapted to accommodate diverse operating conditions. In this work, a flexible topology network concept is proposed to make the adjustment of network structure possible under different operation conditions. The CWS with integrated air cooler and flexible topology network has better overall performance, represented by a mixed integer nonlinear programming (MINLP) model that require advanced tools such as GAMS software. Case studies revealed that the proposed methodology can realize better energy-saving performance, and improve the economic performance under varied operation conditions. The impact of critical flexible nodes on system configuration and economy is achieved by sensitivity analysis.
KW - Air cooler
KW - Cooling water systems
KW - Flexible network
KW - Multiperiod optimization
UR - https://www.scopus.com/pages/publications/85178643670
U2 - 10.1016/j.gce.2023.10.005
DO - 10.1016/j.gce.2023.10.005
M3 - Article
AN - SCOPUS:85178643670
SN - 2096-9147
JO - Green Chemical Engineering
JF - Green Chemical Engineering
ER -