Abstract
The interfacial fracture properties of a carbon fiber reinforced PEEK/titanium fiber metal laminate were studied. Room temperature single cantilever beam tests at quasi-static rates of loading yielded interfacial fracture energy in excess of 2500 J/m2. Interfacial fracture toughness of the system remained well above 2000 J/m2 at 120°C.
Original language | British English |
---|---|
Pages (from-to) | 1819-1823 |
Number of pages | 5 |
Journal | Journal of Materials Science Letters |
Volume | 21 |
Issue number | 23 |
DOIs | |