Hip joint contact pressure distribution during pavlik harness treatment of an infant hip: A patient-specific finite element model

Behzad Vafaeian, Samer Adeeb, Marwan El-Rich, Dornoosh Zonoobi, Abhilash R. Hareendranathan, Jacob L. Jaremko

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Developmental dysplasia of the hip (DDH) in infants under 6 months of age is typically treated by the Pavlik harness (PH). During successful PH treatment, a subluxed/dislocated hip is spontaneously reduced into the acetabulum, and DDH undergoes self-correction. PH treatment may fail due to avascular necrosis (AVN) of the femoral head. An improved understanding of mechanical factors accounting for the success/failure of PH treatment may arise from investigating articular cartilage contact pressure (CCP) within a hip during treatment. In this study, CCP in a cartilaginous infant hip was investigated through patient-specific finite element (FE) modeling. We simulated CCP of the hip equilibrated at 90 deg flexion at abduction angles of 40 deg, 60 deg, and 80 deg. We found that CCP was predominantly distributed on the anterior and posterior acetabulum, leaving the superior acetabulum (mainly superolateral) unloaded. From a mechanobiological perspective, hypothesizing that excessive pressure inhibits growth, our results qualitatively predicted increased obliquity and deepening of the acetabulum under such CCP distribution. This is the desired and observed therapeutic effect in successful PH treatment. The results also demonstrated increase in CCP as abduction increased. In particular, the simulation predicted large magnitude and concentrated CCP on the posterior wall of the acetabulum and the adjacent lateral femoral head at extreme abduction (80 deg). This CCP on lateral femoral head may reduce blood flow in femoral head vessels and contribute to AVN. Hence, this study provides insight into biomechanical factors potentially responsible for PH treatment success and complications.

Original languageBritish English
Article number071009
JournalJournal of Biomechanical Engineering
Volume140
Issue number7
DOIs
StatePublished - 1 Jul 2018

Keywords

  • Contact pressure
  • Dysplasia
  • Finite element analysis
  • Infant hip
  • Pavlik harness

Fingerprint

Dive into the research topics of 'Hip joint contact pressure distribution during pavlik harness treatment of an infant hip: A patient-specific finite element model'. Together they form a unique fingerprint.

Cite this