TY - JOUR
T1 - Exploiting the instability of eccentric tube robots for distal force control in minimally invasive cardiac ablation
AU - Alfalahi, Hessa
AU - Renda, Federico
AU - Messer, Conor
AU - Stefanini, Cesare
N1 - Funding Information:
The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This publication is based upon work supported by the Khalifa University of Science and Technology under Award No. RC2-2018-022 (HEIC) and CIRA-2020-074.
Publisher Copyright:
© IMechE 2021.
PY - 2021/12
Y1 - 2021/12
N2 - While the dilemma of motion tracking and force control in beating-heart surgery is previously addressed using active control architectures and rigid robotic actuators, this work leverages the highly controllable mechanical properties of concentric tube robots for intelligent, design-based force control in minimally invasive cardiac ablation. Briefly, cardiac ablation is the conventional procedure for treating arrhythmia patients, by which exposing the diseased cardiac tissue to Radio-Frequency (RF) energy restores the normal heart rhythm. Yet, the procedure suffers low success rate due to the inability of existing flexible catheters to maintain a consistent, optimal contact force between the tip electrode and the tissue, imposing the need for future repeat surgeries upon disease recurrence. The novelty of our work lies in the development of a statically-balanced compliant mechanism composed of (1) distal bi-stable concentric tubes and (2) a compliant, torsional spring mechanism that provides torque at tubes proximal extremity, resulting in an energy-free catheter with a zero-stiffness tip. This catheter is expected to maintain surgical efficacy and safety despite the chaotic displacement of the heart, by naturally keeping the tip force at an optimal level, not less and not more than the surgical requirement. The presented experimental results of the physical prototype, reflect the feasibility of the proposed design, as well as the robustness of the formulated catheter mathematical models which were uniquely deployed in the selection of the optimal design parameters.
AB - While the dilemma of motion tracking and force control in beating-heart surgery is previously addressed using active control architectures and rigid robotic actuators, this work leverages the highly controllable mechanical properties of concentric tube robots for intelligent, design-based force control in minimally invasive cardiac ablation. Briefly, cardiac ablation is the conventional procedure for treating arrhythmia patients, by which exposing the diseased cardiac tissue to Radio-Frequency (RF) energy restores the normal heart rhythm. Yet, the procedure suffers low success rate due to the inability of existing flexible catheters to maintain a consistent, optimal contact force between the tip electrode and the tissue, imposing the need for future repeat surgeries upon disease recurrence. The novelty of our work lies in the development of a statically-balanced compliant mechanism composed of (1) distal bi-stable concentric tubes and (2) a compliant, torsional spring mechanism that provides torque at tubes proximal extremity, resulting in an energy-free catheter with a zero-stiffness tip. This catheter is expected to maintain surgical efficacy and safety despite the chaotic displacement of the heart, by naturally keeping the tip force at an optimal level, not less and not more than the surgical requirement. The presented experimental results of the physical prototype, reflect the feasibility of the proposed design, as well as the robustness of the formulated catheter mathematical models which were uniquely deployed in the selection of the optimal design parameters.
KW - balanced-stiffness mechanism
KW - beating heart surgery
KW - cardiac ablation
KW - Concentric tube robots
KW - minimally invasive cardiac surgery
KW - passive force control
UR - http://www.scopus.com/inward/record.url?scp=85106233524&partnerID=8YFLogxK
U2 - 10.1177/09544062211007524
DO - 10.1177/09544062211007524
M3 - Article
AN - SCOPUS:85106233524
SN - 0954-4062
VL - 235
SP - 7212
EP - 7232
JO - Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
JF - Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
IS - 23
ER -