TY - JOUR
T1 - Detection of respiratory arousals using photoplethysmography (PPG) signal in sleep apnea patients
AU - Karmakar, Chandan
AU - Khandoker, Ahsan
AU - Penzel, Thomas
AU - Schobel, Christoph
AU - Palaniswami, Marimuthu
PY - 2014/5
Y1 - 2014/5
N2 - Respiratory events during sleep induce cortical arousals and manifest changes in autonomic markers in sleep disorder breathing (SDB). Finger photoplethysmography (PPG) has been shown to be a reliable method of determining sympathetic activation. We hypothesize that changes in PPG signals are sufficient to predict the occurrence of respiratory-event-related cortical arousal. In this study, we develop a respiratory arousal detection model in SDB subjects by using PPG features. PPG signals from 10 SDB subjects (9 male, 1 female) with age range 43-75 years were used in this study. Time domain features of PPG signals, such as 1) PWA-pulse wave amplitude, 2) PPI-peak-to-peak interval, and 3) Area-area under peak, were used to detect arousal events. In this study, PWA and Area have shown better performance (higher accuracy and lower false rate) compared to PPI features. After investigating possible groupings of these features, combination of PWA and Area (PWA + Area) was shown to provide better accuracy with a lower false detection rate in arousal detection. PPG-based arousal indexes agreed well across a wide range of decision thresholds, resulting in a receiver operating characteristic with an area under the curve of 0.91. For the decision threshold (\hbox{PC}-{\rm thresh} =\hbox{25\%}) chosen for the final analyses, a sensitivity of 68.1% and a specificity of 95.2% were obtained. The results showed an accuracy of 84.68%, 85.15%, 86.93%, and 50.79% with a false rate of 21.80%, 55.41%, 64.78%, and 50.79% at PC-{\rm thresh} =\hbox{25\%} or PPI, PWA, Area, and PWA +\hbox{Area} features, respectively. This indicates that combining PWA and Area features reduced the false positive rate without much affecting the sensitivity of the arousal detection system. In conclusion, the PPG-based respiratory arousal detection model is a simple and promising alternative to the conventional electroencephalogram (EEG)-based respiratory arousal detection system.
AB - Respiratory events during sleep induce cortical arousals and manifest changes in autonomic markers in sleep disorder breathing (SDB). Finger photoplethysmography (PPG) has been shown to be a reliable method of determining sympathetic activation. We hypothesize that changes in PPG signals are sufficient to predict the occurrence of respiratory-event-related cortical arousal. In this study, we develop a respiratory arousal detection model in SDB subjects by using PPG features. PPG signals from 10 SDB subjects (9 male, 1 female) with age range 43-75 years were used in this study. Time domain features of PPG signals, such as 1) PWA-pulse wave amplitude, 2) PPI-peak-to-peak interval, and 3) Area-area under peak, were used to detect arousal events. In this study, PWA and Area have shown better performance (higher accuracy and lower false rate) compared to PPI features. After investigating possible groupings of these features, combination of PWA and Area (PWA + Area) was shown to provide better accuracy with a lower false detection rate in arousal detection. PPG-based arousal indexes agreed well across a wide range of decision thresholds, resulting in a receiver operating characteristic with an area under the curve of 0.91. For the decision threshold (\hbox{PC}-{\rm thresh} =\hbox{25\%}) chosen for the final analyses, a sensitivity of 68.1% and a specificity of 95.2% were obtained. The results showed an accuracy of 84.68%, 85.15%, 86.93%, and 50.79% with a false rate of 21.80%, 55.41%, 64.78%, and 50.79% at PC-{\rm thresh} =\hbox{25\%} or PPI, PWA, Area, and PWA +\hbox{Area} features, respectively. This indicates that combining PWA and Area features reduced the false positive rate without much affecting the sensitivity of the arousal detection system. In conclusion, the PPG-based respiratory arousal detection model is a simple and promising alternative to the conventional electroencephalogram (EEG)-based respiratory arousal detection system.
KW - Heart rate variability
KW - photoplethysmography (PPG)
KW - respiratory arousal
KW - sleep apnea
UR - http://www.scopus.com/inward/record.url?scp=84900843100&partnerID=8YFLogxK
U2 - 10.1109/JBHI.2013.2282338
DO - 10.1109/JBHI.2013.2282338
M3 - Article
C2 - 24108482
AN - SCOPUS:84900843100
SN - 2168-2194
VL - 18
SP - 1065
EP - 1073
JO - IEEE Journal of Biomedical and Health Informatics
JF - IEEE Journal of Biomedical and Health Informatics
IS - 3
M1 - 6606860
ER -