TY - GEN
T1 - Detailed dynamic model of an institutional building in hot and humid climate conditions
AU - Masood, Junaid Bin
AU - Hussain, Sajid
AU - AlAlili, Ali
AU - Zaidan, Sara
AU - Al Hajri, Ebrahim
N1 - Funding Information:
The authors would like to acknowledge the financial support of the Petroleum Institute under project LTR15009.
Publisher Copyright:
Copyright © 2017 ASME.
PY - 2017
Y1 - 2017
N2 - This paper is an ASHRAE Level 3 study of the energy audit process carried out in an institutional building, The Umm Shaif Building, of The Petroleum Institute, Abu Dhabi, UAE. It undertakes the study by collecting data and conditional surveys. The energy loss locations are highlighted through psychrometric and infrared camera analysis. The detailed dynamic model has been simulated using the EnergyPlus® simulation engine. The details of the building envelope, and fenestration, the occupancy schedules, the equipment energy consumption and HVAC details are presented. The detailed building model is used to allocate the energy usage and identify key energy consumers. The main results are reported using monthly total energy consumption. The validation and calibration are performed through different statistical metrics including Coefficient of Determination (R2), Root Mean Square Error (RMSE) and Coefficient of Variance Root Mean Square Error (CVRMSE). Finally, energy conservation measures are suggested with the energy and cost savings.
AB - This paper is an ASHRAE Level 3 study of the energy audit process carried out in an institutional building, The Umm Shaif Building, of The Petroleum Institute, Abu Dhabi, UAE. It undertakes the study by collecting data and conditional surveys. The energy loss locations are highlighted through psychrometric and infrared camera analysis. The detailed dynamic model has been simulated using the EnergyPlus® simulation engine. The details of the building envelope, and fenestration, the occupancy schedules, the equipment energy consumption and HVAC details are presented. The detailed building model is used to allocate the energy usage and identify key energy consumers. The main results are reported using monthly total energy consumption. The validation and calibration are performed through different statistical metrics including Coefficient of Determination (R2), Root Mean Square Error (RMSE) and Coefficient of Variance Root Mean Square Error (CVRMSE). Finally, energy conservation measures are suggested with the energy and cost savings.
UR - http://www.scopus.com/inward/record.url?scp=85029372416&partnerID=8YFLogxK
U2 - 10.1115/ES2017-3582
DO - 10.1115/ES2017-3582
M3 - Conference contribution
AN - SCOPUS:85029372416
T3 - ASME 2017 11th International Conference on Energy Sustainability, ES 2017, collocated with the ASME 2017 Power Conference Joint with ICOPE 2017, the ASME 2017 15th International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2017 Nuclear Forum
BT - ASME 2017 11th International Conference on Energy Sustainability, ES 2017, collocated with the ASME 2017 Power Conference Joint with ICOPE 2017, the ASME 2017 15th International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2017 Nuclear Forum
T2 - ASME 2017 11th International Conference on Energy Sustainability, ES 2017, collocated with the ASME 2017 Power Conference Joint with ICOPE 2017, the ASME 2017 15th International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2017 Nuclear Forum
Y2 - 26 June 2017 through 30 June 2017
ER -