TY - JOUR
T1 - Comparison of the Mg2+-Li+ Separation of Different Nanofiltration Membranes
AU - Li, Tingting
AU - Liu, Yueyu
AU - Srinivasakannan, Chandrasekar
AU - Jiang, Xiaobin
AU - Zhang, Ning
AU - Zhou, Guoli
AU - Yin, Shaohua
AU - Li, Shiwei
AU - Zhang, Libo
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/9
Y1 - 2023/9
N2 - Nanofiltration application for the separation of Mg2+-Li+ from salt-lake brines was attempted in the present work. Four different nanofiltration membranes identified in the manuscript as DL, DK, NF-270, and NF-90 were used to treat salt brine with a magnesium to lithium ratio (MLR) of 61, additionally contaminated by the other ions such as Na+, K+, Ca2+, etc. The effect of the dilution factor, operating pressure, circulation rate, and feed pH were assessed to identify the optimal operating conditions for each membrane based on the retention efficiency of each ion. The results showed an insignificant effect of Ca2+ on the retention performance of Mg2+-Li+. Na+ and K+ had a smaller hydration radius and larger diffusion coefficient, which competed with Li+ and altered the separation of Mg2+-Li+. Under the optimal conditions (dilution factor: 40; operating pressure: 1.2 MPa; circulation flow rate: 500 L/h; pH: 7), the retention efficiency of lithium was as low as 5.17%, separation factor (SF) was as low as 0.074, and the MLR in the permeate reduced to 0.088.
AB - Nanofiltration application for the separation of Mg2+-Li+ from salt-lake brines was attempted in the present work. Four different nanofiltration membranes identified in the manuscript as DL, DK, NF-270, and NF-90 were used to treat salt brine with a magnesium to lithium ratio (MLR) of 61, additionally contaminated by the other ions such as Na+, K+, Ca2+, etc. The effect of the dilution factor, operating pressure, circulation rate, and feed pH were assessed to identify the optimal operating conditions for each membrane based on the retention efficiency of each ion. The results showed an insignificant effect of Ca2+ on the retention performance of Mg2+-Li+. Na+ and K+ had a smaller hydration radius and larger diffusion coefficient, which competed with Li+ and altered the separation of Mg2+-Li+. Under the optimal conditions (dilution factor: 40; operating pressure: 1.2 MPa; circulation flow rate: 500 L/h; pH: 7), the retention efficiency of lithium was as low as 5.17%, separation factor (SF) was as low as 0.074, and the MLR in the permeate reduced to 0.088.
KW - ion interception rate
KW - monovalent
KW - multi-valent cations
KW - salt-lake brine
UR - http://www.scopus.com/inward/record.url?scp=85172228957&partnerID=8YFLogxK
U2 - 10.3390/membranes13090753
DO - 10.3390/membranes13090753
M3 - Article
AN - SCOPUS:85172228957
SN - 2077-0375
VL - 13
JO - Membranes
JF - Membranes
IS - 9
M1 - 753
ER -