TY - JOUR
T1 - Chilled water storage feasibility with district cooling chiller in tropical environment
AU - Al Quabeh, Hilal
AU - Saab, Roba
AU - Ali, Mohamed I.H.
N1 - Funding Information:
Masdar city and Masdar Institute of Science and Technology support this study. This support is thankfully acknowledged.
Publisher Copyright:
© 2020, International Centre for Sustainable Development of Energy, Water and Environment Systems SDEWES. All rights reserved.
PY - 2020/3
Y1 - 2020/3
N2 - The difficulties of efficiently operating a chiller cooling system are manifest in the high-energy consumption under partial-cooling loads. The performance of a chiller cooling system declines when operating away from the optimal design conditions, which is typically 75% of chiller capacity. One pathway has been found to overcome this problem using multiple smaller chillers within the same chiller plant, accompanied by a smart control system that is designed and constructed based on the cooling demand profile. Thermal energy storage integration with chiller cooling system is proposed to shave the cooling peak demand. This can be achieved by storing chilled water during the lower electricity-tariff period by the thermal energy storage system, which will then be discharged during the higher tariff-rate, thus, aiming for sustainable operating cost. The present paper studies the feasibility of sensible thermal energy storage to be integrated with two chillers, of 30-ton capacity each, under hot-and-humid climates. A computational model validated with experimental results is developed for three chiller cooling system case scenarios. The smart control scenario, as well as the thermal energy storage scenario results, showed great potential for energy and electricity cost saving. In addition, the carbon dioxide emissions reduction is calculated based on the amount of energy saving.
AB - The difficulties of efficiently operating a chiller cooling system are manifest in the high-energy consumption under partial-cooling loads. The performance of a chiller cooling system declines when operating away from the optimal design conditions, which is typically 75% of chiller capacity. One pathway has been found to overcome this problem using multiple smaller chillers within the same chiller plant, accompanied by a smart control system that is designed and constructed based on the cooling demand profile. Thermal energy storage integration with chiller cooling system is proposed to shave the cooling peak demand. This can be achieved by storing chilled water during the lower electricity-tariff period by the thermal energy storage system, which will then be discharged during the higher tariff-rate, thus, aiming for sustainable operating cost. The present paper studies the feasibility of sensible thermal energy storage to be integrated with two chillers, of 30-ton capacity each, under hot-and-humid climates. A computational model validated with experimental results is developed for three chiller cooling system case scenarios. The smart control scenario, as well as the thermal energy storage scenario results, showed great potential for energy and electricity cost saving. In addition, the carbon dioxide emissions reduction is calculated based on the amount of energy saving.
KW - Chilled water storage
KW - Chiller control
KW - Chillers cooling system
KW - District cooling chillers
KW - Thermal energy storage
KW - Tropical cooling
UR - http://www.scopus.com/inward/record.url?scp=85073522732&partnerID=8YFLogxK
U2 - 10.13044/j.sdewes.d7.0259
DO - 10.13044/j.sdewes.d7.0259
M3 - Article
AN - SCOPUS:85073522732
SN - 1848-9257
VL - 8
SP - 132
EP - 144
JO - Journal of Sustainable Development of Energy, Water and Environment Systems
JF - Journal of Sustainable Development of Energy, Water and Environment Systems
IS - 1
ER -