TY - JOUR
T1 - Assessment of Material Identification Errors, Image Quality, and Radiation Doses Using Small Animal Spectral Photon-Counting CT
AU - Marfo, Emmanuel
AU - Anderson, Nigel G.
AU - Butler, Anthony P.H.
AU - Schleich, Nanette
AU - Carbonez, Pierre
AU - Damet, Jerome
AU - Lowe, Chiara
AU - Healy, Joe
AU - Chernoglazov, Alexander I.
AU - Moghiseh, Mahdieh
AU - Raja, Aamir Y.
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2021/7
Y1 - 2021/7
N2 - Photon-counting CT offers the potential to provide new diagnostic information. In this study, we sought to determine the interplay between material identification errors, image quality indicators, and radiation doses using photon-counting spectral CT, and to determine whether this relationship is replicated in spectral CT scans of mice. Custom-built Perspex phantoms were used to measure signal-to-noise ratio (SNR) and spatial resolution, and to measure radiation dose using thermoluminescent dosimeters. A multicontrast calibration phantom containing inserts with different concentrations of gadolinium (1, 2, 4, and 8 mg/mL), hydroxyapatite rods (0, 54.3, 104.3, 211.7, 402.3, and 808.5 mg/mL) along with water and lipid was used to assess material identification errors. Image acquisition was performed using the MARS photon-counting scanner with four energy channels (30-45, 45-60, 60-78, and 78-118 keV) at four different tube currents (24, 34, 44, and 55μ A). As increased tube current showed no significant effect on material characterization, small animal dosimetry was performed with 24- μ A tube current using two noncontrast mice and one mouse injected with gadolinium. Results demonstrated that a tube current increase from 24 to 54μ A improved the SNR and spatial resolution by <10%, gadolinium identification by <20% (for 1 mg/mL) but radiation dose increased by >160%. Imaging results of the mice showed no obvious artefacts, and the mean absorbed dose measured for the three mice was 27.3±2.4 mGy. The results suggest that the energy resolving capability of photon-counting CT maintains diagnostically relevant image quality with high levels of material discrimination at reduced radiation dose.
AB - Photon-counting CT offers the potential to provide new diagnostic information. In this study, we sought to determine the interplay between material identification errors, image quality indicators, and radiation doses using photon-counting spectral CT, and to determine whether this relationship is replicated in spectral CT scans of mice. Custom-built Perspex phantoms were used to measure signal-to-noise ratio (SNR) and spatial resolution, and to measure radiation dose using thermoluminescent dosimeters. A multicontrast calibration phantom containing inserts with different concentrations of gadolinium (1, 2, 4, and 8 mg/mL), hydroxyapatite rods (0, 54.3, 104.3, 211.7, 402.3, and 808.5 mg/mL) along with water and lipid was used to assess material identification errors. Image acquisition was performed using the MARS photon-counting scanner with four energy channels (30-45, 45-60, 60-78, and 78-118 keV) at four different tube currents (24, 34, 44, and 55μ A). As increased tube current showed no significant effect on material characterization, small animal dosimetry was performed with 24- μ A tube current using two noncontrast mice and one mouse injected with gadolinium. Results demonstrated that a tube current increase from 24 to 54μ A improved the SNR and spatial resolution by <10%, gadolinium identification by <20% (for 1 mg/mL) but radiation dose increased by >160%. Imaging results of the mice showed no obvious artefacts, and the mean absorbed dose measured for the three mice was 27.3±2.4 mGy. The results suggest that the energy resolving capability of photon-counting CT maintains diagnostically relevant image quality with high levels of material discrimination at reduced radiation dose.
KW - Absorbed dose
KW - image quality
KW - material decomposition
KW - Medipix
KW - molecular imaging
KW - photon-counting CT
KW - spectral CT
UR - http://www.scopus.com/inward/record.url?scp=85103765702&partnerID=8YFLogxK
U2 - 10.1109/TRPMS.2020.3003260
DO - 10.1109/TRPMS.2020.3003260
M3 - Article
AN - SCOPUS:85103765702
SN - 2469-7311
VL - 5
SP - 578
EP - 587
JO - IEEE Transactions on Radiation and Plasma Medical Sciences
JF - IEEE Transactions on Radiation and Plasma Medical Sciences
IS - 4
M1 - 9120175
ER -