TY - GEN
T1 - An independent control approach for three-phase four-wire shunt active filter based on three H-bridge topology under unbalanced load conditions
AU - Khadkikar, V.
AU - Chandra, A.
PY - 2008
Y1 - 2008
N2 - This paper presents a simple scheme to compensate the load reactive power, current harmonics, load unbalance, and neutral current in a three-phase four-wire (3P4W) system. The shunt active power filter (APF) consists of three H-bridge single-phase voltage source inverters (VSI) supported by a common DC bus voltage. Thus each phase of 3P4W system can be viewed and controlled as independent phase and/or in conjunction with other phases, and hence it improves the overall system controllability. The 3H-bridge topology also results in the reduction of required DC bus voltage by a maximum factor of √3 , which indeed helps to reduce the inverter rating and thus promises an effective topology for high power applications. In this paper, the single-phase p-q theory based controller is realized to achieve - i) proposed independent phase control approach and ii) load unbalance compensation approach. The 3P4W shunt APF system with both the approaches is first simulated by using MATLAB/ Simulink, and then developed, implemented, and tested in the laboratory using the digital signal processor (DSP) DS1104 of dSPACE. The developed shunt APF system is able to reduce the current total harmonics distortion (THD) up to 2.1%, and the current unbalance factor from 40% to 4.76%.
AB - This paper presents a simple scheme to compensate the load reactive power, current harmonics, load unbalance, and neutral current in a three-phase four-wire (3P4W) system. The shunt active power filter (APF) consists of three H-bridge single-phase voltage source inverters (VSI) supported by a common DC bus voltage. Thus each phase of 3P4W system can be viewed and controlled as independent phase and/or in conjunction with other phases, and hence it improves the overall system controllability. The 3H-bridge topology also results in the reduction of required DC bus voltage by a maximum factor of √3 , which indeed helps to reduce the inverter rating and thus promises an effective topology for high power applications. In this paper, the single-phase p-q theory based controller is realized to achieve - i) proposed independent phase control approach and ii) load unbalance compensation approach. The 3P4W shunt APF system with both the approaches is first simulated by using MATLAB/ Simulink, and then developed, implemented, and tested in the laboratory using the digital signal processor (DSP) DS1104 of dSPACE. The developed shunt APF system is able to reduce the current total harmonics distortion (THD) up to 2.1%, and the current unbalance factor from 40% to 4.76%.
UR - https://www.scopus.com/pages/publications/52349109967
U2 - 10.1109/PESC.2008.4592699
DO - 10.1109/PESC.2008.4592699
M3 - Conference contribution
AN - SCOPUS:52349109967
SN - 9781424416684
T3 - PESC Record - IEEE Annual Power Electronics Specialists Conference
SP - 4643
EP - 4649
BT - PESC '08 - 39th IEEE Annual Power Electronics Specialists Conference - Proceedings
T2 - PESC '08 - 39th IEEE Annual Power Electronics Specialists Conference
Y2 - 15 June 2008 through 19 June 2008
ER -