N2 - This paper proposes an adaptive control for grid connected photovoltaic (PV) system that allows for the active power injection (API) and active power filtering (APF) functionality while allowing the maximum utilization of the PV inverter. This PV system operates in three modes: (i) API only, (ii) API and APF with the full utilization of PV inverter VA capacity, and (iii) API and APF with specific total harmonic distortion (THD) limit for the injected currents. The maximum power point tracking (MPPT) is achieved with perturb and observe method. The proposed algorithm calculates the peak fundamental, harmonic current and then as per the available PV inverter capacity, modifies this value for the full utilization of PV inverter. Adaptive linear neuron (ADALINE) based online Fourier analysis is used to estimate the fundamental and harmonics components of the load and injected currents. The operation of the single stage PV inverter system is analyzed with the proposed control modes for two different atmospheric and load conditions.
AB - This paper proposes an adaptive control for grid connected photovoltaic (PV) system that allows for the active power injection (API) and active power filtering (APF) functionality while allowing the maximum utilization of the PV inverter. This PV system operates in three modes: (i) API only, (ii) API and APF with the full utilization of PV inverter VA capacity, and (iii) API and APF with specific total harmonic distortion (THD) limit for the injected currents. The maximum power point tracking (MPPT) is achieved with perturb and observe method. The proposed algorithm calculates the peak fundamental, harmonic current and then as per the available PV inverter capacity, modifies this value for the full utilization of PV inverter. Adaptive linear neuron (ADALINE) based online Fourier analysis is used to estimate the fundamental and harmonics components of the load and injected currents. The operation of the single stage PV inverter system is analyzed with the proposed control modes for two different atmospheric and load conditions.
KW - Grid connected inverter
KW - maximum powerpoint tracking (MPPT)
KW - photovoltaic (PV) array
KW - voltage oriented control
UR - http://www.scopus.com/inward/record.url?scp=84893573424&partnerID=8YFLogxK
U2 - 10.1109/IECON.2013.6699167
DO - 10.1109/IECON.2013.6699167
M3 - Conference contribution
AN - SCOPUS:84893573424
SN - 9781479902248
T3 - IECON Proceedings (Industrial Electronics Conference)
SP - 388
EP - 393
BT - Proceedings, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society
T2 - 39th Annual Conference of the IEEE Industrial Electronics Society, IECON 2013
Y2 - 10 November 2013 through 14 November 2013
ER -