TY - JOUR
T1 - Active power management of virtual power plant under penetration of central receiver solar thermal-wind using butterfly optimization technique
AU - Dey, Partha Pratim
AU - Das, Dulal Chandra
AU - Latif, Abdul
AU - Suhail Hussain, S. M.
AU - Ustun, Taha Selim
N1 - Funding Information:
This research received no external funding. Authors would like to thank TEQIP-III NIT Silchar for providing technical support for this work.
Publisher Copyright:
© 2020 by the authors.
PY - 2020/9
Y1 - 2020/9
N2 - Striving for the suppression of greenhouse emissions, the modern power network is facing fundamental changes with the utilization of renewable energies (REs) for the future carbon-free society. The utilization of intermittent renewable-green power needs a better power management system and virtual power plant (VPP) can be a vital candidate that meets this demand. This study investigates a coordinated control grid integrated virtual power plant (VPP) in the presence of Central Receiver Solar Thermal System (CRSTS), Wind Turbine Generator (WTG), and Electric Vehicle (EV). To this end, CRSTS employed with thermal storage acts as a dispatchable renewable generating unit and coordinated control of the system units are achieved using the available control strategy on interconnected microgrids in the modified form, employing communication time delay. The proposed control strategy employs the proportional-integral (PI) and PI-derivative (PID) controller. Coordinated power control with real-time communication delay in grid integrated VPP in presence of CRSTS, WTG, and EV is a novel approach. Genetic algorithm (GA), Particle Swarm Optimization (PSO), Slap Swarm Algorithm (SSA), and recent Butterfly Optimization Algorithm (BOA) are used for tuning the necessary control parameters. The results establish the superiority of the BOA over SSA and PSO in suppressing system frequency deviations and tie line power deviation. The analysis of the dynamic response reveals that the consideration of the communication delay in the system expressively impedes the stable operation of the power system.
AB - Striving for the suppression of greenhouse emissions, the modern power network is facing fundamental changes with the utilization of renewable energies (REs) for the future carbon-free society. The utilization of intermittent renewable-green power needs a better power management system and virtual power plant (VPP) can be a vital candidate that meets this demand. This study investigates a coordinated control grid integrated virtual power plant (VPP) in the presence of Central Receiver Solar Thermal System (CRSTS), Wind Turbine Generator (WTG), and Electric Vehicle (EV). To this end, CRSTS employed with thermal storage acts as a dispatchable renewable generating unit and coordinated control of the system units are achieved using the available control strategy on interconnected microgrids in the modified form, employing communication time delay. The proposed control strategy employs the proportional-integral (PI) and PI-derivative (PID) controller. Coordinated power control with real-time communication delay in grid integrated VPP in presence of CRSTS, WTG, and EV is a novel approach. Genetic algorithm (GA), Particle Swarm Optimization (PSO), Slap Swarm Algorithm (SSA), and recent Butterfly Optimization Algorithm (BOA) are used for tuning the necessary control parameters. The results establish the superiority of the BOA over SSA and PSO in suppressing system frequency deviations and tie line power deviation. The analysis of the dynamic response reveals that the consideration of the communication delay in the system expressively impedes the stable operation of the power system.
KW - Butterfly optimization algorithm (BOA)
KW - Central receiver solar thermal system (CRSTS)
KW - Communication time delay
KW - Frequency regulation
KW - Threshold time delay
KW - Virtual power plant (VPP)
UR - http://www.scopus.com/inward/record.url?scp=85090844449&partnerID=8YFLogxK
U2 - 10.3390/SU12176979
DO - 10.3390/SU12176979
M3 - Article
AN - SCOPUS:85090844449
SN - 2071-1050
VL - 12
JO - Sustainability (Switzerland)
JF - Sustainability (Switzerland)
IS - 17
M1 - 6979
ER -