TY - GEN
T1 - A robust comparison approach of velocity data between MRI and CFD based on divergence-free space projection
AU - Koltukluoglu, Taha Sobri
AU - Hirsch, Sven
AU - Binter, Christian
AU - Kozerke, Sebastian
AU - Szekely, Gabor
AU - Laadhari, Aymen
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2015/7/21
Y1 - 2015/7/21
N2 - Recent achievements in 4D flow MRI increased the interest of CFD-MRI studies, which require comparison of velocity fields from both approaches for validation purposes. A novel flow regularization approach is proposed to provide a ground truth and to perform robust, mathematically reasonable comparisons between CFD and MRI. Our suggested method projects the measured and denoised data into the same space as the computational domain and applies the Helmholtz-Hodge theorem to recover the divergence-free property of the flow field by decomposing the velocity field into its divergence-free, curl-free and harmonic components. Furthermore, an aortic phantom study has been set-up under fully controlled laminar flow conditions with helical flow patterns to validate the proposed method using phase-contrast MRI measurements, whereas a dynamic stenosed case was used under turbulent flow conditions to analyse the robustness of applied pre-processings including the denoising of MRI data and the decomposition of velocity vector field.
AB - Recent achievements in 4D flow MRI increased the interest of CFD-MRI studies, which require comparison of velocity fields from both approaches for validation purposes. A novel flow regularization approach is proposed to provide a ground truth and to perform robust, mathematically reasonable comparisons between CFD and MRI. Our suggested method projects the measured and denoised data into the same space as the computational domain and applies the Helmholtz-Hodge theorem to recover the divergence-free property of the flow field by decomposing the velocity field into its divergence-free, curl-free and harmonic components. Furthermore, an aortic phantom study has been set-up under fully controlled laminar flow conditions with helical flow patterns to validate the proposed method using phase-contrast MRI measurements, whereas a dynamic stenosed case was used under turbulent flow conditions to analyse the robustness of applied pre-processings including the denoising of MRI data and the decomposition of velocity vector field.
UR - http://www.scopus.com/inward/record.url?scp=84944313731&partnerID=8YFLogxK
U2 - 10.1109/ISBI.2015.7164136
DO - 10.1109/ISBI.2015.7164136
M3 - Conference contribution
AN - SCOPUS:84944313731
T3 - Proceedings - International Symposium on Biomedical Imaging
SP - 1393
EP - 1397
BT - 2015 IEEE 12th International Symposium on Biomedical Imaging, ISBI 2015
PB - IEEE Computer Society
T2 - 12th IEEE International Symposium on Biomedical Imaging, ISBI 2015
Y2 - 16 April 2015 through 19 April 2015
ER -